Altosa-XL-GEMINI PTA Balloon

Special features:

  • Advanced Technology For Dual Dilatation In Large Vessels
  • Very Low Profile With Fast Inflation & Deflation Times
  • High Pressure To Ensure Excellent Results

The Altosa-XL-GEMINI PTA Balloon

  • The AltoSa-XL GEMINI PTA Balloon is especially designed for double dilatation in large vessels. Zero-Shoulder Technology provides extra safety during the procedure.
  • The high-pressure performance combined with low profile makes the AltoSa-XL GEMINI PTA Balloon an excellent choice to treat difficult large vessels and non-vascular lesions.
  • New Nylon Material (NNM) for high puncture resistance and reliable multiple dilatations with fast inflation & deflation time and non compliant vessel application
  • Optimal stent retention for Open / Closed and Hybrid cell designed stents.

Please note: The inner balloon is adapted to the required sizes of the outer Balloon.
It has the same length as the outer balloon and offers a RBP of 6 atm.

AltoSa XL PTA Balloon

Special features:

The AltoSa-XL medium to high pressure PTA catheter is based on a over the wire coaxial shaft and is 110cm in total length. The high puncture resistant non to semi compliant balloon material is mounted on the distal end of the shaft and is designed to reopen strong calcifications in large peripheral vessels.
The proximal end hosts the hub for inflation and deflation of the distal balloon and the guide wire lumen is 0.035“. The balloon is diameter specific and varies in length from 2cm, 3cm, 4 cm, and 6cm with diameters starting from 14mm and incrementally moving in 2mm up to 30mm in diameter. The right balloon size and diameter should be choosen by the physician according to the patients needs. (Note: special sizes might be available on request).

Specific features:

This unique medium to high pressure PTA is available in the lengths of 110 cm. The highly puncture resistant balloon is mounted on the distal end of the shaft. The balloon can expand up to its desired diameter. The highly flexible shaft will provide excellent push even in very tortuous vasculature. Medium to high pressures are uniquely used in calcified lesions I large vessels and non-vascular applications.

The AltoSa XL PTA Balloon

  • Flexible shaft
    The highly flexible shaft allows the physician to advance the balloon in tortuous anatomy.
  • Highly resistant NYPE balloon
    This particular balloon features medium to high pressures with fast inflation and deflation time.
  • Atraumatic soft tip
    A flexible tapered Tip allows smooth tracking to manoeuvre the balloon to its final destination even through very tight lesions.
  • Low sheath compatibility
    The low profile allows a smaller sheath compatibility, which makes the AltoSa-XL the 1st choice of balloons to be combined with modern vascular interventions such as large stents and treating highly resistant lesions.

AltoSa SFT Compliant Large Lumen PTA Balloon

Special features:

The AltoSa-SFT compliant PTA balloon is a peripheral balloon for the use in the peripheral vascular system. It is providing the operator a safe tool to expand peripheral stent graft devices, which need a final expansion and wall attachment. The fast inflation and deflation time will ultimately save valuable time in the OR and provide extra safety for this procedure.

Specific features:

This particular balloon is available in the lengths of 100 cm and 65 cm. The highly expandable polyurethane balloon is mounted on the distal end of the shaft. The balloon can gently expand up to 46mm diameter and the balloon length is 4cm. The guidewire lumen is 0.035” and this highly flexible shaft will provide excellent push even in very tortuous vasculature.

The AltoSa-SFT PTA peripheral moulding balloon

  • Flexible shaft
    The highly flexible shaft allows the physician to advance the balloon in tortuous anatomy.
  • Polyurethane balloon
    This particular balloon features very fast inflation and deflation time which allows the physician to minimize procedural time and x-ray exposure.
  • Atraumatic soft tip
    A very soft flexible tapered Tip allows smooth tracking to manoeuvre the balloon to its final destination without getting caught in the stent struts of the stent graft.
  • Low sheath compatibility
    The very low profile allows a smaller sheath compatibility, which makes the AltoSa-SFT the 1st choice to be combined with modern vascular stent grafts.

AltoSa Premier Extra High Pressure PTA Balloon

Special features:

The AltoSa-Premier maximum high pressure PTA catheter is based on a over the wire coaxial shaft and is 0.035“ guide wire compatible and is 75cm in length.
The highly resistant nylon balloon is mounted on the distal end oft he shaft and can resist and reopen even strongest calcifications and fibrous lesions.
The proximal end hosts the hub for inflation and deflation of the distal balloon and the guide wire lumen. The balloon is diameter specific and length is 4 cm and should be choosen by the physician according to the patients needs.
Ideal for venous high pressure dilatation.

Specific features:

This unique high pressure PTA is available in the lengths of 75 cm. The highly puncture resistant nylon balloon is mounted on the distal end of the shaft. The balloon can expand up to its desired diameter and the balloon length is 4cm. The highly flexible shaft will provide excellent push even in very tortuous vasculature. High pressures are uniquely used in venous lesions and in highly calcified large iliacs.

The AltoSa-Premier PTA peripheral high pressure balloon

  • Flexible shaft
    The highly flexible shaft allows the physician to advance the balloon in tortuous anatomy.
  • Highly resistant NYPE nylon Balloon
    This particular balloon features very high pressures with fast inflation and deflation time.
  • Atraumatic soft tip
    A flexible tapered Tip allows smooth tracking to maneuverer the balloon to its final destination even through very tight lesions.
  • Low sheath compatibility
    The low profile allows a smaller sheath compatibility, which makes the AltoSa-Premier the 1st choice to be combined with modern vascular venous stents and to treat highly resistant resistant lesions.

Generally AndraTec products are CE approved. Some of the products, however, are CE pending. Please contact us for more details.